You are here: Symbol Reference > Dew Namespace > Dew.Signal Namespace > Classes > TStoredSpectrumAnalyzer Class > TStoredSpectrumAnalyzer Members
Dew Signal for .NET
ContentsIndexHome
TStoredSpectrumAnalyzer Members Public Properties
Public Properties
 
Name 
Description 
 
Set active to false to suppress the propagation of the Pull request and the subsequent call to the Update method. 
 
Stores the amplitude of the spectrum. 
 
Used to store the number of averages made. 
 
Holds the parameters for the frequency bands.  
 
Returns the bandwidth of the spectrum in [Hz]. 
 
Returns the upper bandwidth edge of the signal.  
 
Returns the lower bandwidth edge of the signal. 
 
Set this property to true, to request computation using complex numbers.  
 
If True, the conjugate symmetric part of the frequency spectrum is to be computed. 
 
If True, the conjugate symmetric part of the frequency spectrum will be placed in 0.5..1.0 Fs (as returned by the FFT), and not between -0.5..0.0 Fs. 
 
If True, the component will pass on the udpate request to the connected component. 
 
This is Descriptor, a member of class TStaticSpectrumAnalyzer. 
 
Dt 
Returns the distance in seconds between two consecutive samples of the signal on which the frequency spectrum is based. 
 
Set this property to request computation in 32bit/64bit precision with real/complex numbers.  
 
Set this property to true to lock changes to FloatPrecision property.  
 
Defines number of harmonics to be used when calculating statistical parameters from the amplitude spectrum. 
 
Returns the frequency resolution in Hz. 
 
Specifes the Input spectrum for the analysis component.  
 
Define the integration/differenation of the frequency spectrum.  
 
Set this property to false, to request computation in 32bit floating point precision, 64bit, if true.  
 
Number to label the object when it is an item in the List. 
 
This is LdBSpan, a member of class TCustomSpectrumAnalyzer. 
 
Defines the length of the spectrum.  
 
Set it to True, to obtain the logarithm of the spectrum in dB.  
 
Defines the base of the logarithmic spectrum.  
 
Defines the scaling of the logarithmic spectrum.  
 
Defines the span of the logarithmic spectrum in dB.  
 
Specify how to apply the logarithm to the spectrum.  
 
Defines the width of the main lobe. Each frequency component in the frequency spectrum should theoretically be infinitely thin. 
 
Stores the frequency, amplitude and phase of selected frequency bins. 
 
Stores the maximum value of the Amplt spectrum found by the MinMaxAmplt method. 
 
Holds the index at which the maximum amplitude was found by the MinMaxAmplt method. 
 
Stores the maximum value of the Phase spectrum found by the MinMaxPhase method. 
 
Stores the minimum value of the Amplt spectrum found by the MinMaxAmplt method. 
 
Stores the minimum value of the Phase spectrum found by the MinMaxPhase method. 
 
The event is triggered after the call to the Update method. 
 
If assigned, this event will be called instead of a call to Bands.Update method.  
 
The event is triggered just before the call to the Update method. 
 
The event is triggered after the OnAfterUpdate event. Use this event to update any associated charts or graphs or result tables. 
 
If the Input property is not assigned, the component will call OnGetInput. 
 
The event is called after a call to InternalUpdate, OnAfterUpdate and OnDisplayUpdate from within the Update method. 
 
The event is triggered when ParamUpdate method is called. The ParamUpdate method is usually called by component editors when a value was changed by the user and the editor was "Live".  
 
If assigned, this event will be called instead of a call to Peaks.Update method.  
 
Pointer to the component that manages peak analysis.  
 
Stores the phase of the spectrum.  
 
This property determines how to handle the phase of the frequency spectrum. 
 
Specify the range of the phase spectrum. 
 
Defines the units of phase. (radian, degrees). 
 
Returns the state of the pipe after the last update. 
 
Holds the parameters needed to generate a spectrum analysis report. Requires that the descriptor property is properly filled up.  
 
Before the frequency analysis, the signal can be circularly rotated by a specified number of samples. Rotation defines the number of samples.  
 
Defines the sampling frequency of the signal on which the frequency spectrum is based. 
 
Defines the length of the signal on which the frequency spectrum is based in seconds. 
 
Frequency spectrum will be scaled by a scale factor.  
 
Specifies the spectrum type to be computed.  
 
Specifies the Integration method of the stored Spectrum.  
 
Specifies the Logarithmic flag of the stored Spectrum.  
 
Specifies the SpectrumType of the stored Spectrum.  
 
Set this property to True, to prevent calling OnNotifyUpdate from the Update Method. 
 
Set it to True to indicate, that valid signals will be connected to the Input or Inputs properties. 
 
Defines the level of zero padding of the source signal. 
Copyright (c) 1999-2024 by Dew Research. All rights reserved.