You are here: Symbol Reference > Dew Namespace > Dew.Signal Namespace > Classes > TSignalRead Class > TSignalRead Members
Dew Signal for .NET
ContentsIndexHome
TSignalRead Members Public Properties
Public Properties
 
Name 
Description 
 
Set active to false to suppress the propagation of the Pull request and the subsequent call to the Update method. 
 
If True, the file format will be automatically determined from the file name extension. 
 
Return the bandwidth of the signal. 
 
Returns the upper bandwidth edge of the signal. 
 
Returns the lower bandwidth edge of the signal. 
 
Get or set the number of channels multiplexed in the data property. 
 
Set this property to true, to request computation using complex numbers.  
 
If True, the component will pass on the udpate request to the connected component. 
 
Data 
Stores the result of the processing. 
 
Dt 
Time between two consecutive samples. 
 
Defines the format of the file, if AutoFileFormat property is False. 
 
Defines the file name to be read from or written to. 
 
Set this property to request computation in 32bit/64bit precision with real/complex numbers.  
 
Set this property to true to lock changes to FloatPrecision property.  
 
Warn about compressed files varying Length read. 
 
Set FrameNumber to position the read cursor within the current record. 
 
Returns the number of frames per second according to Framing and overlapp properties. 
 
Defines the method to traverse a multi-record the file. 
 
Frequency resolution obtained, if an FFT algorithm would be run on the data. 
 
Connector property to obtain a pointer to the TSignal component holding the data to be processed. 
 
Connector property to obtain a pointer to the TSignal component holding the data to be processed. 
 
Set this property to false, to request computation in 32bit floating point precision, 64bit, if true.  
 
Number to label the object when it is an item in the List. 
 
Specifies how to handle the end of file.  
 
Get or set the length of the signal in samples. 
 
Loop 
If true, looping will be enabled.  
 
Stores the time stamps and amplitude of selected samples. 
 
Stores the maximum amplitude of the signal found by the MinMax method. 
 
Read Only. Determine the maximum number of frames.  
 
MaxX 
Use the MaxX property to store the time stamp (in seconds) of the right most sample. 
 
Stores the minimum amplitude of the signal found by the MinMax method. 
 
MinX 
Use the MinX property to store the time stamp of the left-most sample. 
 
Read only. Returns the number of records contained in the current file. 
 
The event is triggered after the call to the Update method. 
 
The event is triggered just before the call to the Update method. 
 
The event is triggered after the OnAfterUpdate event. Use this event to update any associated charts or graphs or result tables. 
 
If the Input property is not assigned, the component will call OnGetInput. 
 
The event is called after a call to InternalUpdate, OnAfterUpdate and OnDisplayUpdate from within the Update method. 
 
The event is triggered when ParamUpdate method is called. The ParamUpdate method is usually called by component editors when a value was changed by the user and the editor was "Live".  
 
Event triggered when Process command is selected from the drop-down menu in the component editor. 
 
Triggered after RecordPosition changes. 
 
Define the overlapping in percent of consequtive frames when reading the file. 
 
Define the overlapping in sampels of consequtive frames when reading the file. 
 
Returns the state of the pipe after the last update. 
 
Append zeros to then end of file.  
 
Append zeros to end of file.  
 
Read the precision of the data being read from the file. 
 
Read only. Returns the length of the current record in samples for one channel. 
 
Set RecordNumber to move the read cursor within the file to the record with RecordNumber number. 
 
Set and get position in samples.  
 
Read only. Returns the length of the current record in seconds for one channel. 
 
Set RecordTimePosition in seconds to position the read cursor within the current record. 
 
Defines the sampling frequency of the signal. 
 
The length of the signal in seconds. 
 
Defines a scale factor to be applied to just read data. 
 
Specifies the lower file range limit.  
 
Specifies the upper file range limit.  
 
Set this property to True, to prevent calling OnNotifyUpdate from the Update Method. 
 
Set it to True to indicate, that valid signals will be connected to the Input or Inputs properties. 
Copyright (c) 1999-2024 by Dew Research. All rights reserved.