TSignalMultiRate Class

Source: SignalProcessing.cs · Assembly: Dew.Signal
ComponentTMtxComponentTAnalysisTSignalTSignalMultiRate

public class TSignalMultiRate : TSignal

Abstract class for multi-rate digital filters.

Abstract class for multi-stage, multi-rate decimation and interpolation FIR filters.

An in depth explanation of the methods used can be found in [1] Chapter 7.3 (Digital resampling).

References:

[1] "Understanding digital signal processing.", Richard G. Lyons, Prentice-Hall, 2001.

Properties

NameTypeDescription
ActiveBooleanSet active to false to suppress the propagation of the Pull request and the subsequent call to the Update method.
AudioSignalBooleanAdjust filters for audio signal.
BandWidthDoubleReturn the bandwidth of the signal.
BandwidthHDoubleReturns the upper bandwidth edge of the signal.
BandwidthLDoubleReturns the lower bandwidth edge of the signal.
BlockAssignBooleanBlock streaming of specific properties when storing only a "template".
ChannelCountInt32Get or set the number of channels multiplexed in the data property.
ComplexBooleanSet this property to true, to request computation using complex numbers.
ContinuousBooleanIf True, the component will pass on the udpate request to the connected component.
DataTVecStores the result of the processing.
DtDoubleTime between two consecutive samples.
EditorActiveBooleanReturns True, if the component editor is displayed.
ExternalTapsBooleanEnables user specified filter.
FactorInt32Decimation/Interpolation factor.
FilterDelayDoubleReturns the filter delay in number of samples of the final sampling frequency.
FloatPrecisionTMtxFloatPrecisionSet this property to request computation in 32bit/64bit precision with real/complex numbers.
FloatPrecisionLockBooleanSet this property to true to lock changes to FloatPrecision property.
HalfBandBooleanFilters out upper half of the bandwidth.
HzResDoubleFrequency resolution obtained, if an FFT algorithm would be run on the data.
InitializedBooleanWhen set to false, the next call to the update method will reinitialize the FIR filters.
InputTAnalysisConnector property to obtain a pointer to the TSignal component holding the data to be processed.
IsDoubleBooleanSet this property to false, to request computation in 32bit floating point precision, 64bit, if true.
ItemDoubleDefault property to access values of a real signal.
ItemNumberInt32Number to label the object when it is an item in the List.
LengthInt32Get or set the length of the signal in samples.
MarksTMarkListStores the time stamps and amplitude of selected samples.
MaxAmpltDoubleStores the maximum amplitude of the signal found by the MinMax method.
MaxXDoubleUse the MaxX property to store the time stamp (in seconds) of the right most sample.
MinAmpltDoubleStores the minimum amplitude of the signal found by the MinMax method.
MinXDoubleUse the MinX property to store the time stamp of the left-most sample.
OnAfterUpdateTNotifyEventThe event is triggered after the call to the Update method.
OnBeforeUpdateTNotifyEventThe event is triggered just before the call to the Update method.
OnDisplayUpdateTNotifyEventThe event is triggered after the OnAfterUpdate event. Use this event to update any associated charts or graphs or result tables.
OnGetFilterTapsTNotifyEventTriggered when ExternalTaps is false.
OnGetInputTNotifyEventIf the Input property is not assigned, the component will call OnGetInput.
OnNotifyUpdateTNotifyEventThe event is called after a call to InternalUpdate, OnAfterUpdate and OnDisplayUpdate from within the Update method.
OnParameterUpdateTNotifyEventThe event is triggered when ParamUpdate method is called. The ParamUpdate method is usually called by component editors when a value was changed by the user and the editor was "Live".
PipeStateTPipeStateReturns the state of the pipe after the last update.
ReferenceTReferenceListStores a list of components that have to be notified, when this component is destroyed.
RippleDoubleMaximum ripple allowed in the passband and in the stopband.
SamplingFrequencyDoubleDefines the sampling frequency of the signal.
SamplingTimeDoubleThe length of the signal in seconds.
ScaleFactorDoubleDefines the factor by which the signal will be scaled.
SuspendNotifyUpdateBooleanSet this property to True, to prevent calling OnNotifyUpdate from the Update Method.
TransBWDoubleDefines the width of the transition band of the FIR filter used for interpolation/decimation.
UsesInputsBooleanSet it to True to indicate, that valid signals will be connected to the Input or Inputs properties.

Methods

NameDescription
AllowStreamingReturns the negatated value of BlockAssign.
AppendAppends Sample to the end of the signal.
AssignAssign values of all published properties from Source.
AssignTemplateAssign values of "template-like" published properties from Source.
CopyCopies signal Data and sampling frequency information.
CrestCompute the CREST parameter.
EditorClassTo be overriden in descendanr classses.
InitFiltersFirTaps and FinalStageTaps do not hold valid filter taps until InitFilters has been called.
InputsDirtyIf all Inputs[i] are dirty the function returns true.
InternalPullWhen called, the method will pass Update requests recursively to all connected objects.
InvalidateNotifies all connected components that this component has fresh data.
LoadFromStreamLoad the component from Src stream.
LoadTemplateFromFileLoad a template from file.
LoadTemplateFromStreamLoad a template from stream.
MarksToStringsConvert marks to strings.
MinMaxFind minimum and maximum amplitude and store the result in the MinAmplt and MaxAmplt properties.
ParamUpdateThe method can be assigned to some other component even handler, as a notification that a parameter has changed and that Self should consider a recalculation.
PeakFind the maximum deviation of the signal from its mean value.
PipeResetRecursively processes all connected components backward and calls Reset method.
ProcessFilter Src and place the result in Dst.
PullRequest recalculation of the entire chain of all connected components.
PullUntilEndCalls Pull until pipeEnd is returned.
ResetThe same as setting Initialized to false.
SaveTemplateToFileSave template to file.
SaveTemplateToStreamSave template to stream.
SaveToStreamSave the component to Dst stream.
SizeAssign the size of the signal from Src.
UpdateRequest recalculation of the data and place the result in Self.
UpdateNotifyCall this method only, if SuspendNotifyUpdate is True.
ValuesToStringsConvert values to strings.

Events

NameDescription
OnAfterUpdateEventThe event is triggered after the call to the Update method.
OnBeforeUpdateEventThe event is triggered just before the call to the Update method.
OnDisplayUpdateEventThe event is triggered after the OnAfterUpdate event. Use this event to update any associated charts or graphs or result tables.
OnGetFilterTapsEventTriggered when ExternalTaps is false.
OnGetInputEventIf the Input property is not assigned, the component will call OnGetInput.
OnNotifyUpdateEventThe event is called after a call to InternalUpdate, OnAfterUpdate and OnDisplayUpdate from within the Update method.
OnParameterUpdateEventThe event is triggered when ParamUpdate method is called. The ParamUpdate method is usually called by component editors when a value was changed by the user and the editor was "Live".